Skip to main content
Skip to content
Case File
efta-efta01223584DOJ Data Set 9Other

Zorro Management, LLC

Date
Unknown
Source
DOJ Data Set 9
Reference
efta-efta01223584
Pages
6
Persons
0
Integrity

Summary

Ask AI About This Document

0Share
PostReddit

Extracted Text (OCR)

EFTA Disclosure
Text extracted via OCR from the original document. May contain errors from the scanning process.
Zorro Management, LLC 49 Zorro Ranch Road, Stanley, NM 87056 Credit Card Reques Form Date of Request: Amount Requested: 12/02/18 813,589.00 Payee: RMC Electric Payee Addres Payee Contact: O Check box if GL coding is split Invoice NJMemo: GL Description: 'Wells & Water System GL Code: 15082 GL Amount: $13,589.00 GL Memo: Purchase/Install VF0 for Well Pump in Well B Invoice NJMemo: GL Description: GL Code: GL Amount: K Check box if additional pages are included Other Notes/ Instructions: GL Memo: Attached E Mail Back Up Date Approved by Manager: Manager Signature: 12/02/18 EFTA01223584 RMC Electric Invoice PO Box 10645 Albuquerque, NM 87184-0645 Bill To Zorro Ranch 49 Zone Ranch RD Stanley NM 87056 Date Invoice # 11/29/2018 39x Ship To n. Number Terms Rep Ship Via F 0 B Project 11/29/2018 Quantity Item Code Description Price Each Amount This ABS 3 Phase VFD it comes Irrigation design package. It is a Factory pre wired package in its own Nemo 3R inclosurc ready to install and program. This unit will take care of most under and over voltage problems. we will monitor voltage for a week and have records of voltage problem to insure system will work. 3AUA0000159493 I ABB ACS550-PD-075A-2+C192, 74.8 RATED AMPS, DIMENSIONS 49 Flx 32.36 Wx 22.88 I) - OUTDOOR RATED, NEMA 3R/UL CERTIFIED ENCLOSURE - PADLOCKABLE ENCLOSURE ON THE MAIN DOOR AND CONTROL DOOR - ADVANCED DRIVE KEYPAD - 4 POLE SERVICE ENTRANCE RATED DISCONNECT - SURGE/LIGHTNING PROTECTION - CONDENSATION HEATER - FIAND/OFF/AUTO SELECTOR SWITCH Total Page 1 EFTA01223585 RMC Electric Invoice Bill To 702TO itallell Date Invoice # 11/29/2018 398 Ship To Number Terms Rep Ship Via F.O.B. Project I 1129/2018 Quantity Item Code Description Price Each Amount - SPEED POTENTIOMETER - PILOT LIGHTS FOR DRIVE READY, RUN AND FAULT - CONTROL POWER TRANSFORMER WITH AN EXTRA 100VA FOR CUSTOMER USE - EMBEDDED MODBUS RTU (RS485) PROTOCOL (ADDITIONAL COMMUNICATION PROTOCOLS AVAILABLE) I year warranty on new VFD / 2 years with certified startup Startup, programming and training assistance available from Lane Electric supply. Materials ABB 25 HP VFD 9,000.00 9,000.00T Materials voltage recording 600.00 600.OOT Materials labor to install and program 1.500.00 1,500.007 Materials Start up and tech support with 2 year warranty 1,600.00 1,600.001' 4 week lead time Sales Tax 7.00% 889.00 Total 513,589.00 Page 2 EFTA01223586 12/1/2018 Devil - Fwd: ZM VD Web B M Gmail Fwd: ZM VD Well B 1 message Brice Gordon > Fri, Nov 30. 2018 at 9:27 AM To: Zorro Ranch > Zorro Ranch From Date: Mon, Jul 23, 2018 at 5:04 PM Subject: ZM VD To: Rich Kahn Cc: Zorro Ranch Rich Attached for your review Proposal for the replacement for the VFD for the Well Pump in Well B, $13,598.00 2015 Proposal for existing VFD, $13,412.00 Rogers Drilling 2015 the Well Pump for Well B was upgraded to 50 gpm 3 phase motor, in doing so a single phase to 7.5hp 3 phase VFD was installed. The existing drive is very susceptible to voltage fluctuation and as of date the VFD needs to be reset frequently during the day. This situation its making very difficult to achieve a constant water supply for domestic and irrigation proposes. It will need to be address if we are to achieve the qty of water required under the permit E 7871. RMC Electric sourced the company that will supply the drive and the support The new drive is 25hp vs the existing 7.7hp drive, this will handle the power fluctuations from the power company. Can we proceed with purchase and install regards Once Gordon Stanley, NM LSJ-GSJ, USVI Ph: (505) 934 2809 Brice Gordon Stanley, NM LSJ-GSJ, USVI Ph: 2 attachments hepe://mtel.google.corn/maiVu/2/ik=c841321eee&view=pt&search=ellepermthld=thread-fiS3A1618565609600360784asimpl=msg-653A16185656096 1/2 EFTA01223587 Estimate Name Address Date Estimate # 6/21/2018 109 7 P.O. No. Project Item Description Total This ABB 3 Phase VFD it comes Irrigation design package. It is a Factory pre wired package in its own Nema 3R inclosure ready to install and program. This unit will take care of most under and over voltage problems. we will monitor voltage for a week and have records of voltage problem to insure system will work. 3AUA0000159493 1 ABB ACS550-PD-075A-2+C192, 74.8 RATED AMPS, DIMENSIONS 49 Hx 32.36 Wx 22.88 D - OUTDOOR RATED. NEMA 3RfUL CERTIFIED ENCLOSURE - PADLOCICABLE ENCLOSURE ON THE MAIN DOOR AND CONTROL DOOR - ADVANCED DRIVE KEYPAD - 4 POLE SERVICE ENTRANCE RATED DISCONNECT - SURGE/LIGHTNING PROTECTION - CONDENSATION HEATER - HAND/OFF/AUTO SELECTOR SWITCH - SPEED POTENTIOMETER - PILOT LIGHTS FOR DRIVE READY. RUN AND FAULT - CONTROL POWER TRANSFORMER WITH AN EXTRA I00VA [Total Page 1 EFTA01223588 Name / Address Estimate Date Estimate # 6/21/2018 109 Zorro Ranch P.O. No. Project Item Description Total Materials Materials Materials Materials FOR CUSTOMER USE - EMBEDDED MODBUS RTU (RS485) PROTOCOL (ADDITIONAL COMMUNICATION PROTOCOLS AVAILABLE) 1 year warranty on new VFD / 2 years with certified startup Startup, programming and training assistance available from Lane Electric supply. ABB 25 HP VFD voltage recording labor to install and program Start up and tech support with 2 year warranty 4 week lead time Sales Tax 9,000.OOT 600.OOT 1.500.OOT 1,600.001 889.00 Total 513.589.00 Page 2 EFTA01223589

Technical Artifacts (2)

View in Artifacts Browser

Email addresses, URLs, phone numbers, and other technical indicators extracted from this document.

Phone(505) 934 2809
Phone16185656096

Forum Discussions

This document was digitized, indexed, and cross-referenced with 1,400+ persons in the Epstein files. 100% free, ad-free, and independent.

Annotations powered by Hypothesis. Select any text on this page to annotate or highlight it.